The ISCO 2150 area velocity flow meter features a smart area velocity probe which is built on digital electronics, so the analog level is digitized in the sensor itself to overcome electromagnetic interference.
The area velocity probe is factory calibrated for a 3 meter span at different temperatures. This calibration eliminates drift in the level signal and provides long term level stability. This reduces recalibration frequency and completely eliminates span recalibration.
In the field, the ISCO 2150 flow meter can be powered by either two alkaline, or ISCO Rechargeable lead acid batteries, within a 2191 Battery Module. The battery has a life of up to 15 months at 15 minute data storage intervals due to highly efficient power management.
Standard Features of the 2150 include:
Manufactured by: Teledyne ISCO
Model: ISCO 2150 Area Velocity Flow Meter Rental
Partially filled-pipes
Open channels - uniform and non uniform
Streams
Irrigation channels
Short term flow studies
Permanent - real time telemetry
2150 Flow Module | |
Size (HxWxD) | 2.9 x 11.3 x 7.5 in (74 x 287 x 191 mm) |
Weight | 2.0 lb (0.9 kg) |
Materials of Construction | High-impact polystyrene, stainless steel |
Enclosure (self-certified) | NEMA 4X, 6P (IP68) |
Temperature Range | -40° to 140°F (-40° to 60°C) operating and storage |
Power Required | 12 VDC nominal (7.0 to 16.6 VDC), 100 mA typical, 1 mA standby |
Power Source | Typically, an Isco 2191 Battery Module, containing 2 alkaline or 2 rechargeable lead-acid batteries. (Other power options are available; ask for details.) |
Typical Battery Life | (using 15-minute data storage interval) Energizer® Model 529 alkaline - 15 months; Isco rechargeable lead-acid - 2.5 months |
Program Memory | Non-volatile programmable flash; can be updated using PC without opening enclosure; retains user program after updating. |
Built-in Conversions | |
Flow Rate Conversions | Up to 2 independent level-to-area conversions and/or level-to-flow rate conversions. |
Level-to-Area Conversions | Channel Shapes - round, U-shaped, rectangular, trapezoidal, elliptical, with silt correction; Data Points - Up to 50 level-area points. |
Level-to-Flow Conversions | Most common weirs and flumes; Manning Formula; Data Points (up to 50 level-flow points); 2-term polynomial equation |
Total Flow Calculations | Up to 2 independent, net, positive or negative, based on either flow rate conversion |
Data Handling and Communications | |
Data Storage | Non-volatile flash; retains stored data during program updates. Capacity 395,000 bytes (up to 79,000 readings, equal to over 270 days of level and velocity readings at 15-minute intervals, plus total flow and input voltage readings at 24-hour intervals) |
Data Types | Level, velocity, flow rate 1, flow rate 2, total flow 1, total flow 2, input voltage, temperature |
Storage Mode | Rollover; 5 bytes per reading. |
Storage Interval | 15 or 30 seconds; 1, 2, 5, 15, or 30 minutes; or 1, 2, 4, 12, or 24 hours; Storage rate variable based on level, velocity, flow rate, total flow, or input voltage |
Data Retrieval | Serial connection to PC or optional 2101 Field Wizard module; optional modules for spread spectrum radio; land-line or cellular modem; 1xRTT. Modbus and 4-20 mA analog available. |
Software | Isco Flowlink for setup, data retrieval, editing, analysis, and reporting |
Multi-module networking | Up to four 2100 Series Flow Modules, stacked and/or remotely connected. Max distance between modules 3300 ft (1000 m). |
Serial Communication Speed | 38,400 bps |
2150 Area Velocity Sensor | |
Size (HxWxD) | 0.75 x 1.3 x 6.0 in (19 x 33 x 152 mm) |
Cable (Length x Diameter) | 25 ft x 0.37 in (7.6 m x 9 mm) standard. Custom lengths available on request. |
Weight (including cable) | 2.2 lbs (1 kg) |
Materials of Construction | Sensor - Epoxy, chlorinated polyvinyl chloride (CPVC), stainless steel; Cable - Polyvinyl chloride (PVC), chlorinated polyvinyl chloride (CPVC) |
Operating Temperature | 32° to 140°F (0° to 60°C) |
Level Measurement | |
Method | Submerged pressure transducer mounted in the flow stream |
Transducer Type | Differential linear integrated circuit pressure transducer |
Range | (standard) 0.033 to 10 ft (0.010 to 3.05 m); (optional) up to 30 ft (9.15 m). |
Maximum Allowable Level | 34 ft (10.5 m) |
Accuracy | ±0.01 ft from 0.033 to 10 ft, (±0.003 m from 0.01 to 3.05 m) |
Long-Term Stability | ±0.023 ft/yr (±0.007 m/yr) |
Compensated Range | 32° to 122°F (0° to 50°C) |
Velocity Measurement | |
Method | Doppler ultrasonic, frequency 500 kHz |
Typical Minimum Depth | 0.08 ft (25 mm) |
Range | -5 to +20 ft/s (-1.5 to +6.1 m/s) |
Accuracy | (in water with uniform velocity profile, speed of sound = 4850 ft/s, for indicated velocity range); ±0.1 ft/s from -5 to 5 ft/s (±0.03 m/s from -1.5 to +1.5 m/s); ±2% of reading from 5 to 20 ft/s (1.5 to 6.1 m/s) |
Temperature Measurement | |
Accuracy | ±3.6°F (±2°C) |
2191 Battery Module | |
Size (HxWxD) | 6.0 x 9.6 x 7.6 in (152 x 244 x 193 mm) |
Weight (without batteries) | 3.2 lb (1.4 kg) |
Materials of Construction | High-impact polystyrene, stainless steel |
Enclosure (self certified) | NEMA 4X, 6P, (IP68) |
Batteries | Two 6-volt Energizer Model 529* alkaline (25 Ahrs capacity) or Isco Rechargeable Lead-acid (5 Ahrs capacity) recommended. *Note Energizer 529 ER does not give specified life. |