Benefitting from a fully-welded steel fitting, the 911/E flow meter is suitable for flow velocities up to 12m/s (39.4ft/s). The metering tube liners are available made of hard or soft rubber, PTFE or Novolak. This flowmeter is most commonly used in the industries of pulp and paper, mining, or chemical.
The 911/E flow meter has an pulse alternating field, according to Faradays law where an electric voltage is induced in a conductor moving through a magnetic field.
Manufactured by: Siemens-Milltronics
Model: FM911 MagFlow Meter for Sludge & Slurries
Pulp and paper industry
Mining industry
Measuring Range | 0 to 10 m/s |
Nominal Sizes | From DN 15 to DN 1000 (½" to 40") |
Accuracy | ± 0.5 % of flow rate |
Operating Pressure | Max. 40 bar (Max. 580 psi) |
Ambient Temperature | From -20 to 60 °C (-4 to 140 °F) |
Medium Temperature | From -20 to 150 °C (-4 to 300 °F) |
Liners | Neoprene PTFE Hardrubber Linatex Novolak |
Electrodes | AISI 316 Ti (mat. No. 1.4571/316 Ti) Hastelloy C4 (mat. No. 2.4610) Platinum head with shaft (mat. No. 1.4571/316Ti) Titanium Tantalum |
Enclosure Sensor | IP67 (NEMA 4x) IP68 (NEMA 6) - optional |
Material | Carbon steel |