The Siemens Transmag 2 flow transmitters are designed for heavy-duty applications such as pulp & paper stock over 3%; heavy mining slurries and mining slurries with magnetic particles. This is a truly robust option compatible with911 flowmeters.
It has high signal-to-noise ratio by transient phenomenon - 10 times higher than the pulse DC version, 2 times higher than the pulse AC system in the market.
Measurement of magnetically conductive media is possible by measurement of the field strength in the transducer. Solids up to 85% and two phase materials are not a problem for this technology. It comes complete with self-cleaning electrodes, self-diagnostics for error detection and a mulit-lingual display.
Manufactured by: Siemens-Milltronics
Model: Transmag 2 Flow Transmitter
Pulp and paper industry
Mining industry
Slurries & Sludges
Measuring Range | 0 to 10 m/s |
Nominal Sizes | From DN 15 to DN 1000 (½" to 40") |
Accuracy | ± 0.5 % of flow rate |
Operating Pressure | Max. 40 bar (Max. 580 psi) |
Ambient Temperature | From -20 to 60 °C (-4 to 140 °F) |
Medium Temperature | From -20 to 150 °C (-4 to 300 °F) |
Liners | Neoprene PTFE Hardrubber Linatex Novolak |
Electrodes | AISI 316 Ti (mat. No. 1.4571/316 Ti) Hastelloy C4 (mat. No. 2.4610) Platinum head with shaft (mat. No. 1.4571/316Ti) Titanium Tantalum |
Enclosure Sensor | IP67 (NEMA 4x) IP68 (NEMA 6) - optional |
Material | Carbon steel |