The PanaFlow LZ is offered as a one- or two-path wetted, ultrasonic flow meter that brings all of the advantages of ultrasonic technology at an affordable price.
Unlike other flow measurement technologies, the PanaFlow LZ requires no maintenance as it does not have any obstruction in the flow path that could clog the line nor does it have any moving parts that could be damaged by the flowing fluid. PanaFlow LZ measurements are not affected by changing process conditions, such as temperature, pressure and conductivity variations. In addition, because the measurements do not drift over time, no periodic calibration is required. Thus, the PanaFlow LZ is a very attractive flow meter, providing a lower overall total cost of ownership along with the superb reliability and performance expected from a Panametrics ultrasonic flow meter.
Several electronics packages can be paired with the PanaFlow meter system to provide local or remote electronics. For local electronics, the XMT1000 transmitter is used. Other electronics platforms are available for remote locations. With both electronics configurations, the system is preprogramed with setup information for your application making it is quick and easy to install.
Manufactured by: Panametrics
Model: PanaFlow LZ System - Ultrasonic Inline Flow Meter
Pipeline metering
Water/cooling water/wastewater
Internal allocation metering
Loading/unloading
Fuel oils
Hydrocarbon liquids
Crude oils
Chemicals
Blending
Solvents
Weak acid solutions
Operation and performance | |
Fluid types | Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles |
Flow measurement | Correlation Transit Time model |
Paths | 1 Path: 2 in. to 24 in. (50 mm to 600 mm) pipe |
Pipe sizes | 2 in. to 24 in. (50 mm to 600 mm) |
Pipe material | Carbon steel Stainless steel (316/316L) |
Accuracy | ±0.5% of reading for velocity above 2 ft/s (0.6 m/s) up to 40 ft/s (12.2 m/s) with a resolution of ± 2 mm/s Accuracy statement assumes measurement of a single phase homogenous liquid with a fully developed symmetrical flow profile passing through the meter. Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification. |
Repeatability | ±0.3% of reading typical |
Range (bidirectional) | ±0.1 to 40 ft/s (0.03 to 12.19 m/s) |
Measurement parameters | Dependent upon meter electronics used. Please refer to individual flow meter electronics product data sheet. |
Electronics/transmitter | |
Temperature range | Operating: -40°F to 140°F (-40°C to +60°C) Storage: –67°F to 167°F (–55°C to 75°C) |
Meter body and transducer | |
Pressure rating | Up to maximum allowable flange operating pressure at temperature, per ASME B16.5 |
Temperature range | WT Transducers: BWT Transducers: Temperature rating of -20°C if used with carbon steel meter body. |
Transducer material | 316L Stainless steel (buffers) |
Meter body materials | Carbon steel Stainless steel (316/316L) |
Certification | Electronics/Transducers: Flow Cell: NACE MR0175 and MR0103 |
Transducer cables | |
Integral cables |
|
Remote cables | ATEX/IECEx: Armoured RG62 for ATEX/IECEx Remote cables are not included and must be ordered separately. Maximum cable length is 1000 ft (300 m). |