The ruggedised DM5E Thickness Gauge is ergonomically designed for use with one hand and is just 223g including batteries with up to 60 hours of operation. Certified to EN 15317 it has a backlit LCD data display so visible in all lighting conditions. It has a sealed, watertight and dust-proof membrane keypad which features function and arrow keys to navigate a simple and intuitive menu with a wide range of features, including Min/Max capture, B-Scan generation, alarms, and differential thickness measurement to allow instant comparison between measured and nominal thickness.
Manufactured by: Waygate Technologies
Model: DM5E Corrosion Thickness Gauge
Wall thickness measurements on:
Pipelines
Pressure vessels
Storage tanks
DM5E Family | ||
Operating Principle | Ultrasonic, pulse echo measurement method | |
Measuring Range | Depends on probe and material, 0.60 mm to 508 mm (0.025" to 20.00") in IP to 1st BW measurement mode, 2.00 mm to 127.0 mm (0.079" to 5.00") in dual-multi measurement mode, the coating thickness range shall be 0.3 mm to 2.50 mm (0" to 0.098"). | |
Measuring Resolution | 0.01 mm default - selectable 0.01, 0.1 mm (0.001" default - selectable 0.001", 0.01") | |
Material Velocity Range | 0.508 to 18.699 mm/msec (0.0200" to 0.7362"/msec) | |
Material Velocity Resolution | 1 m/s (0.0001"/msec) | |
Units | Inch or millimeter | |
Calibration | One-point cal, on-block and off-block, two-point cal | |
Pulser | Excitation Pulse | Spike pulser |
Voltage | 120 V into 50 ohm load, using 20 MHz oscilloscope | |
Receiver | Bandwidth | 500 KHz to 12 MHz @ -3 dB |
Gain | Automatic gain control | |
Display Type | High-resolution graphical LCD, 64 x 128 pixels, 53.0 mm x 27.0 mm with backlight and adjustable contrast | |
Update Rate | 4 Hz or 8 Hz, user selectable, 24 Hz scan mode capture rate | |
Thickness value display | NORMAL view mode | 5 Digit, 10.6 mm (0.4") high |
B-SCAN view mode | 5 Digit, 2.55 mm (0.1") high | |
Display of Last Reading | Solid filled or hollow digits indicate coupled or uncoupled condition | |
Setups | 9 standard setups for probes | |
Alarm Settings | Minimum and maximum alarms, range of 0.25 mm to 508 mm, 0. (0.010" to 20.00") reading alternates between solid and hollow when alarms are enabled and violated | |
Power Requirements | 2 AA size batteries | |
Battery Life/ Operating Time | Approximately 60 hours | |
Instruments Shut-off | Selectable ALWAYS ON or AUTO OFF after 5, 10, 15, 30 minutes of inactivity | |
Language | Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese | |
I/O Connectors | Transducer | Dual Lemo 00 (coax) |
Mini-USB | Mini USB to PC | |
Temperature | Operating | -10°C to +50°C (+10°F to +120°F) |
Storage | -20°C to +60°C (-10°F to +140°F) | |
Weight | 223 g (0.597 lb) including batteries | |
Size | 138 mm x 32 mm x 75 mm | |
Shock | IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms impulse half sinusoidal wave applied 6 times per axis | |
Sealing | IEC529 / IP54, dust proof/dripping water proof as per IEC 529 specifications for IP54 classification |