Repeatability |
Mass flow rate |
±0.2% of rate |
Volumetric flow rate |
±0.1% of rate |
Temperature |
±0.2°F (± 0.1°C) |
Pressure |
±0.05% of full scale |
Density |
±0.1% of reading |
Stability over 12 months |
Mass flow rate |
±0.2% of rate |
Volumetric flow rate |
Negligible |
Temperature |
±0.9°F (± 0.5°C) |
Pressure |
±0.1% of full scale |
Density |
±0.1% of reading |
Response time |
Adjustable from 1 to 100 seconds |
Operating |
Process standard temperature (code ST) |
-40 to 500°F (-40 to 260°C) |
Process high temperature (code HT) |
Up to 750°F (400°C) |
Ambient operating |
-40 to 140°F (-40 to 60°C) |
Ambient storage |
-40 to 185°F (-40 to 85°C) |
Power requirements |
- DC2 option: 12-36 VDC loop powered, 25mA, 1W max, loop
powered (single output)
- DC2 option: 12-36 VDC loop powered, 25mA, 1W max, loop powered (single output)
- DC4 option: 12-36 VDC, 300 mA max, 9W max, (multiple outputs)
- DC4POE option: 12-28 VDC or power over Ethernet, 5W max, (multiple outputs)
- AC option: 100-240 VAC, 50/60 Hz, 5 watt (multiple outputs)
|
Display |
Alphanumeric 2 line x 16 character LCD digital display: Six pushbuttons for full field configuration. Pushbuttons can be operated with magnetic wand without removal of enclosure covers. Display can be mounted in 90° intervals for better viewing |
Output signals |
- Analog: 4-20 mA, loop powered for volumetric meters
- Alarm: Solid state relay, 40 VDC
- Totalizer Pulse: 50 millisecond, 40 VDC
- DC2 Option: One analog, one totalizer pulse, HART
- DC4, DC4POE, and AC Option: Up to three analog signals,
three alarms, one totalizer pulse, HART, Modbus, BACnet
|
Physical |
Wetted materials |
316L stainless steel standard, plus:
- PTFE based thread sealant on models with pressure
transducer
- PTFE packing on standard temperature models with
packing gland
- Graphite-based packing on high temperature models with
packing gland
- Carbon steel and Hastelloy C meter bodies optional
|
Certifications |
- FM/FMC Class I, Division 1, Groups B, C and D, Class II, III,
Division 1, Groups E, F and G
- Type 4x and IP66, T6, Ta = -40°C - +60°C
- ATEX II 2 G Ex d IIB + H2 T6, II 2 D Ex tD A21 IP66 T85°C, Ta =-40°C - +60°C
- IECEx Ex d IIB + H2 T6, Ex tD A21 IP66 T85°C, Ta = -40°C - +60°C
|