The new Panaflow MV 82 is an insertion multivariable vortex mass flow meter, suitable for measuring mass, temperature and pressure. Also allows volumetric flow measurement and density. The MV 82 is capable of measuring most qases, liquids and steam without the need to recalibrate.
The insertion multivariable mass vortex flow meters design consists of a vortex shredding velocity sensor, an RTD temperature sensor and a solid state pressure transducer that measures the mass flow rate of steam, gases and liquids. Most meter types measure temperature and pressure at different points as the devices are not generally installed at the same points. That can mean that mass flow readings can be extremely inaccurate. The MV82 mass flow meter measures these parameters at the same location giving more accurate process measurements.
The MV82 is very cost effective as it integrates pressure and temperature with a simplified system. This saves on initial capital costs and also installation costs. All parameters can be sent straight to your data acquisition system, so there is no need to purchase additional instrumentation.
There are a variety of MV82 vortex flow meters available so the user can choose the option with the most suitable configuration to suit their application.
Manufactured by: Panametrics
Model: MV82 Vortex Insertion Flowmeter
High temperature and high velocity steam
Power generation - fuel and steam applications
Industrial - HVAC, district energy management
Commercial - building, campus and facility energy management
Oil and gas - allocation of natural gas
Petrochemical - mass balancing, reaction processes heating
Performance | |
Accuracy | Mass flow rate accuracy for gas and steam based on 50- 100% of pressure range |
PanaFlow MV80 flow meter accuracy | ||
Process variable | Liquids | Gas and steam |
Volumetric flow rate | ± 1.2% of rate | ± 1.5% of rate |
Mass flow rate | ± 1.5% of rate | ± 2% of rate |
Temperature | ± 2°F (± 1°C) | ± 2°F (± 1°C) |
Pressure | ± 0.3% of full scale | ± 0.3% of full scale |
Density | ± 0.3% of reading | ±0.5% of reading |
Repeatability | |
Mass flow rate | ±0.2% of rate |
Volumetric flow rate | ±0.1% of rate |
Temperature | ±0.2°F (± 0.1°C) |
Pressure | ±0.05% of full scale |
Density | ±0.1% of reading |
Stability over 12 months | |
Mass flow rate | ±0.2% of rate |
Volumetric flow rate | Negligible |
Temperature | ±0.9°F (± 0.5°C) |
Pressure | ±0.1% of full scale |
Density | ±0.1% of reading |
Response time | Adjustable from 1 to 100 seconds |
Operating | |
Process standard temperature (code ST) | -40 to 500°F (-40 to 260°C) |
Process high temperature (code HT) | Up to 750°F (400°C) |
Ambient operating | -5 to 185°F (-20 to 85°C) |
Ambient storage | -40 to 185°F (-40 to 85°C) |
Power requirements |
|
Display | Alphanumeric 2 line x 16 character LCD digital display Six pushbuttons for full field configuration Pushbuttons can be operated with magnetic wand without removal of enclosure covers Display can be mounted in 90° intervals for better viewing |
Output signals |
|
Physical | |
Wetted materials | 316L stainless steel, plus:
|
Certifications |
|