Operation and performance |
Fluid types |
Liquids: acoustically conductive fluids, including most clean liquids, and many liquids with small amounts of entrained solids or gas bubbles. |
Flow measurement |
Correlation transit time model |
Accuracy |
3 to 24 in (80 to 600 mm)
- ±0.25% of reading for velocities above 1.6 ft/s (0.5 m/s)
- ±1.25 mm/s for velocities below 1.6 ft/s (0.5 m/s)
2 in (50 mm) - ±0.5% of reading for velocities above 1.6 ft/s (0.5 m/s)
- ±2.5 mm/s for velocities below 1.6 ft/s (0.5 m/s)
Accuracy statement assumes measurement of a single phase homogenous liquid with a fully developed symmetrical flow profile passing through the meter (typically 10 diameters upstream and 5 diameters downstream of straight pipe run).
Applications with piping arrangements that create an asymmetrical flow profile may require extended piping straight runs and/or flow conditioning for the meter to perform to this specification. |
Calibration |
All meters are water calibrated at ambient conditions and include a calibration certificate.
- 3 points as found 2, 5, and 10 ft/s (0.6, 1.5 and 3 m/s) and 2 points as left 3 and 7 ft/s (0.9 and 2.1 m/s)
|
Repeatability |
- ±0.15% of reading 3 to 24 in (80 to 600 mm)
- ±0.2% of reading 2 in (50 mm)
|
Range (bidirectional) |
-82 to 82 ft/s (-25 to 25 m/s) |
Meter body/transducer system |
Meter body materials |
- Low temperature carbon steel: ASTM SA352 Gr. LCC
- Stainless steel: ASTM SA351 Gr. CF8M
- Duplex stainless steel: ASTM SA995 GR. CD3MWCuN
|
Transducer system and material |
- LX transducers with inserts
- 316 SS or A479 UNS S32760 (Duplex)
- Wetted components Seals
- FKM or EPDM
|
Process fluid temperature range |
- Local mount: -40°F to 302°F (-40°C to 150°C*)
- Remote mount: -40°F to 302°F (-40°C to 150°C)
*Maximum process temperature is 203°F (95°C) when additional analog input/output options are selected |
Pressure range |
Up to maximum allowable flange operating pressure at temperature per ASME B16.5 or EN1092-1 |
Piping design |
- ASME B31.3
- NACE MR0103/MR0175
- PED PER B31.3, CAT II, A2
- CRN
|
Transmitter |
Enclosures |
Powder coated aluminum (copper free) or stainless steel (SS316) conformal coated |
Classifications |
US/CAN: Class I, Division 1, Groups B, C, D;
Class I, Zone 1, Ex db IIB+H2 T6...150C;
IP 66/67 Type 4X
SINGLE SEAL
ATEX/IECEx: Ex db IIB+H2 T6...150C FISCO outputs
Ta = -40°C to +65°C, IP 66/67
Operating: -40°F to 149°F (-40°C to +65°C*)
Storage: -40°F to 158°F (-40°C to 70°C)
*Maximum ambient temperature is 60°C (140°F when foundation fieldbus option selected) |
Transmitter mounting |
Local or remote mounting |
Paths |
- Three paths : 3 to 24 in (80 to 600 mm)
- Two paths : 2 in (50 mm)
|
Display |
English
128 x 64 mono-color LCD display, configurable for single or dual measurement parameters |
Keypad |
Built-in magnetic, six-button, lockable keypad |
Cable entries |
¾” NPT
M20 adapters |
Power supplies |
Universal 100-240 VAC 50/60 Hz ±10% or 12 to 28 VDC (15W max, 7W typical) |
Standard inputs/outputs |
- One 4 to 20 mA isolated output, 600 Ohm maximum load, NAMUR NE43
- One additional output, may be configured as either a pulse or frequency output.
|
Optional inputs/outputs |
Analog and digital I/O are available in specific combinations. See ordering information below for details: - Two additional 4 to 20 mA isolated outputs, 600 Ohm maximum load, NAMUR NE43
- One or two 4 to 20 mA isolated inputs, 24-VDC loop power, NAMUR NE43
- One or two isolated, three-wire RTD (temperature) inputs, –148°F to 662°F (–100°C to 350°C), 100 Ohm or 1000 Ohm platinum
- One or two isolated, four-wire RTD (temperature) inputs, –148°F to 662°F (–100°C to 350°C), 100 Ohm or 1000 Ohm platinum
|
Digital interfaces |
- Standard: RS485/Modbus®
- Optional: HART® 7.0 protocol, with four dynamic variables, includes one additional 4 to 20 mA analog output NAMUR NE43
- Optional: Foundation Fieldbus® FISCO, LAS capable NAMUR NE107 with five AI blocks and a PID block
Note: Maximum ambient operating temperature range of transmitter with
Foundation Fieldbus® is +60°C./td>
|