Siemens SITRANS FX vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in one solution and include integrated pressure and temperature compensation. The FX300 is a compact vortex flowmeter in a single or dual transmitter version, and is suitable for measuring industrial steam, gases, as well as conductive and non-conductive liquids. E.g. steam (saturated steam, superheated steam), industrial gases (compressed air, nitrogen, liquefied gases, flue gases), and conductive and non-conductive liquids (demineralized water, boiler feed water, solvents, heat transfer oil).
Siemens SITRANS F X vortex flowmeters detect the frequency at which alternating vortices are shed from a bluff body inserted into the flow stream in order to measure flow rate. This principle of measurement
                          is known as Von Karman's vortex street principle: alternating vortices form behind an object in a stream. The frequency of the alternating vortices is proportional to the flow rate. The passage of a vortex causes a slight stress on a pick-up placed downstream of the bluff body. The stress is picked up and counted as pressure surges by a dual Piezo crystal placed inside the wing.
The main applications of the SITRANS vortex flowmeters can be found in the following
                            sectors:
                          
                                                Manufactured by: Siemens-Milltronics
                                                Model: SITRANS FX300 Vortex Flowmeter
                                            
                    Chemical
Petrochemical
Oil and gas
Power plants
Saturated steam
Super-heated steam
Energy monitoring                        
| Measuring Range | Use calculation and sizing program | 
| Nominal Size | Flanged version: From DN15 to DN300 (1/2 inch to 12 inch) Sandwich version: From DN15 to DN100 (1/2 inch to 4 inch)  | 
                                
| Accuracy |  Steam and gases: +/- 1% Liquids: +/- 0.75%  | 
                                
| Input / Output | 4 - 20 mA, Pulse/Freq. 0.5 Hz, 24V DC as NAMUR | 
| Communication | HART | 
| Power Supply | 24V DC as NAMUR | 
| Operational Pressure | Max 100 Bar (higher pressure on request) | 
| Ambient Temperature | From -40° to 85°C (-40° to 185 °F) | 
| Medium Temperature | From -40 °C to 240 °C (-40° to 464 °F) | 
| Display |  2 lines, 10 characters per line Languages: German, English and French  | 
                                
| Transmitter Enclosure | IP 66 / 67 Aluminum Seawater Resistant | 
| Sensor Material | 1.4404/316L, Hastelloy C22 (on request) | 
| Approval |  ATEX ll 2G EEx d ia [ia] llC T6 FM Class I, II, III Div. 1 & 2  |