The SITRANS LH300 pressure transmitter is a submersible sensor for measuring hydrostatic level. It comes in a variety of measurement ranges to suit the application and explosion protection can be added. For easy installation, a cable hanger and junction box are available as accessories.
The LH300 provides reliable readings with a small error in measurement (0.15% typical).
Manufactured by: Siemens-Milltronics
Model: SITRANS LH300 Pressure Transmitter
Water/waste water supply
Drinking water facilities
For use in unpressurized/open vessels and wells
Desalination plants
Shipbuilding
Mode of operation | |
Measuring principle | piezo-resistive |
Input | |
Measured variable | Hydrostatic level |
Measuring range | Max. permissible operating pressure |
Special measuring ranges
Measuring range
Special measuring ranges
|
|
Output | |
Output signal | 4 ... 20 mA |
Measuring accuracy | According to IEC 60770-1 |
Error in measurement at limit setting including hysteresis and reproducibility | ≤ 0.15 % of upper range value (typical) ≤ 0.3 % of upper range value (maximum) |
Long-term stability | ≤ 0.15 % of upper range value/year (zero and span) |
Operating conditions | |
Ambient conditions
|
|
Degree of protection according to IEC 60529 | IP68 |
Design | |
Weight (pressure transmitter) | ≈ 0.4 kg ( ≈ 0.88 lb) |
Weight (cable) | 0.08 kg/m (≈ 0.059 lb/ft) |
Maximal freely suspended length |
300 m (990 ft) |
Electrical connection | Cable with 2 conductors, vent pipe and integrated humidity filters |
Material (Seal diaphragm) | Al2O3 ceramic, 99.6 % |
Material (Enclosure) |
Stainless steel, mat. no. 1.4404/316L and 1.4539/904L (sea water applications) respectively |
Material (Gasket) | FPM (standard) EPDM (optional) |
Material (Connecting cable) | PE (standard/drinking water applications) FEP (for aggressive media) |
Material (Cap) | Stainless steel, PPE or ETFE |
Auxiliary Power |
|
Terminal voltage on pressure transmitter UB | 10 ... 33 V DC for transmitter without explosion protection 10 ... 30 V DC for transmitter with intrinsic safety explosion protection |
Auxiliary power | |
Terminal voltage on pressure transmitter UB | 10 ... 33 V DC 10 ... 30 V DC for transmitter with intrinsic safety explosion protection |
Certificates and approvals | |
Drinking water approval (ACS) | 17 ACC NY 055 |
EAC | TC N RU ?-DE.??02.B.05092 |
Underwriters Laboratories (UL) | ML File No. E344532, issued 2017-08-17 |
Shipbuilding approval (LR) | LR_18/20074 |
Shipbuilding approval (DNV/GL) | TAA00000CE |
Shipbuilding approval (BV) | 56926/A0 BV |
Shipbuilding approval (ABS) | HG1881314_P |
Shipbuilding approval (RINA) | ELE067319XG |
Pressure equipment directive | The transmitter is not subject to the pressure equipment directive (PED 2014/68/EU) |
Explosion protection | |
ATEX |
SEV 16 ATEX 0121 |
IEC Ex | IEC Ex SEV 16.0003 |
EAC Ex | TC RU C-DE.AA87.B.00324 |
Intrinsic safety "i" - Marking | II 1 G Ex ia IIC T4 Ga |