The Orion Star™ A213 Dissolved Oxygen Benchtop Meter features a large backlit LCD which displays dissolved oxygen in percent saturation or concentration and temperature along with time, date, sample ID, user ID and calibration information. Accurate results are easy with automatic temperature, manual salinity and choice of automatic or manual barometric pressure compensation. The A213 is automatically recognizes and accepts the Orion™ polarographic and RDO optical/luminescence-based probes eliminating any concerns regarding barometric pressure compensation. Calibration is carried out using water-saturated air, air saturated water, a winkler titration or zero point calibration.
There are many other features which make the Orion Star™ A213 Dissolved Oxygen Meter the perfect choice and these are:
Manufactured by: Thermo Scientific
Model: A213 Dissolved Oxygen Benchtop Meter
Accuracy (Polarographic DO) | ±0.2 mg/L; ±2 % saturation |
Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, 10% of reading from 20 to 50mg/L; ±2 % saturation |
Battery Life | 800 hours |
Battery Type | Four AA (sold separately) |
Data Points | 2000 |
Description | Orion Star A213 RDO/Dissolved Oxygen/Temperature Benchtop Meter |
Display Type | Graphic LCD with backlight |
Hertz | 50/60Hz |
Inputs | 9-pin Mini-DIN (RDO or polarographic DO with temperature probe), stirrer input |
Outputs | USB, RS232 |
Range (Polarographic DO) | 0 to 90 mg/L; 0 to 600 % saturation |
Range (RDO) | 0 to 50 mg/L; 0 to 500 % saturation |
Relative Humidity Range | 5 to 85 %, non-condensing |
Resolution (Polarographic DO) | 0.01, 0.1 mg/L; 0.1, 1 % saturation |
Resolution (RDO) | 0.01, 0.1 mg/L; 0.1, 1 % saturation |
Salinity Factor | 0 to 45ppt |
Saturation Range (RDO) | 0 to 500% Saturation |
Saturation Range (Polarographic DO) | 0 to 600% Saturation |
Sensor Types | Polarographic or RDO (optical) DO probe - purchase separately |
Accuracy (Temperature) | ±0.1°C |
Range (Temperature) | 5 to +105°C |
Resolution (Temperature) | 0.1°C |
Voltage | 90 to 260VAC |
Warranty | 3 year meter replacement |
Percent Saturation Resolution (RDO) | 0.1, 1% Saturation |
Calibration Modes | Water-saturated air, manual (Winkler), air-saturated water, zero point |
Certifications/Compliance | IP-54 |
Percent Saturation Relative Accuracy (Polarographic DO) | ±2% Saturation |
Percent Saturation Relative Accuracy (RDO) | ±2% Saturation |
Percent Saturation Range (Polarographic DO) | 0 to 600% Saturation |
Saturation Range | 0 to 600 % Saturation(polarographic); 0 to 500 % Saturation(RDO) |
Saturation Resolution | 0.1, 1% Saturation |