The Manta F35 Anti-Fouling Multiprobe provides water quality measurement for a wide range of parameters.
Different sizes of multiprobe are available depending on the number of sensors required. The F30 can hold up to 7 sensors whilst the F35 can hold up to 11 sensors.
Available parameters:
Manufactured by: Eureka
Model: Manta F35 Anti-Fouling Multiprobe
Groundwater interaction
Saltwater intrusion
Surface water
Reservoir and lake monitoring
Estuary monitoring
Watershed and source water protection
Beach monitoring
Storm water runoff
NPS monitoring
Vertical profiling
Temperature | |
Range | -5° C - 50° C |
Accuracy | ±0.1% |
Resolution | 0.01° C |
Dissolved 0xygen (% Sat) | |
Range | 0 - 200% 200 - 500% |
Accuracy | ±2.4% ±7.2% |
Resolution | 0.1 |
Optical DO | |
Dissolved oxygen (mg/L) | |
Range | 0 - 25 mg/L |
Accuracy | 1% of reading or 0.02 mg/L, whichever is greater |
Resolution | 0.01 mg/L; |
Dissolved oxygen (% Sat) | |
Range | 0 - 200 % |
Accuracy | 1% of reading or 0.02 mg/L, whichever is greater |
Resolution | 0.1 |
Conductivity (SC) | |
Range | 0 - 100 mS/cm |
Accuracy | 1% reading ± 1 count |
Resolution | 4 digits |
Salinity | |
Range | 0 - 70 PSU (PPT) |
Accuracy | ±1% of reading or 0.1 PSU, whichever is greater |
Resolution | 4 digits |
TDS | |
Range | 0 - 65 g/L |
Accuracy | Calculated from Conductivity |
Resolution | 4 digits |
Turbidity | |
Optical 90° Nephelometric Mechanical Wiper | |
Range | 0 - 3000 NTU |
Accuracy | 0 - 100 < 1% of reading 100 - 400 < 3% of reading over 400 < 5% of reading |
Resolution | 0.1 |
pH | |
Range | 0 - 14 units |
Accuracy | ± 0.2 units |
Resolution | 0.01 units |
ORP | |
Range | -999 - 999 mV |
Accuracy | ± 20 mV |
Resolution | 1 mV |
Depth | |
Range | 10m, 25m, 50m, 100m, 200m |
Accuracy | ± 0.1% Full scale |
Resolution | 0.01 m |
Level | |
Range | 0 - 10 meters |
Accuracy | 0.003 meters |
Resolution | 0.001 |
Ammonium | |
Range | 0 - 100 mg/L Nitrogen |
Accuracy | ± 10% of reading or 2 mg/L whichever is greater |
Resolution | 0.1 mg/L -N |
Nitrate | |
Range | 0 - 100 mg/L Nitrogen |
Accuracy | ± 10% of reading or 2 mg/L whichever is greater |
Resolution | 4 digits |
Chloride | |
Range | 0.5 - 18,000 mg/L |
Accuracy | ± 10% of reading or 2 mg/L whichever is greater |
Resolution | 4 digits |
TDG | |
Range | 400 - 1400 mm/Hg |
Accuracy | ± 0.5 mm/Hg |
Resolution | 0.1 mm/Hg |
Chlorophyll a | |
Range | 0.03 - 50 µg/L |
Accuracy | ± 3% |
Resolution | 0.01 µg/L |
Rhodamine | |
Range | 0.04 to 1000 ppb |
Accuracy | ± 3% |
Resolution | 0.01 ppb |
Blue green algae | |
Range | 100 - 200,000 cells/mL |
Accuracy | ± 3% |
Resolution | 20 cells/mL |