The Thermo Scientific AquaSensors AquaChlor free Chlorine sensor will measure accurately in clean water processes between 4 and 9 pH. Best performance is achieved when used in applications
where process pH, flow, pressure and temperature are stable. When used with the Thermo Scientific AV38 Local Display/Controller and a pH DataStick sensor, measured hypochlorous acid (HOCl) and
hypochlorite ion (OCl-) concentrations can be used to determine free chlorine levels present.
Features of the AquaChlor Monitoring System include an easyto-replace sensor membrane cap, temperature compensation, a turn-key reagent free design and a compact mounting footprint.
For optimum measurement performance the unique flow chamber maintains regulated pressure and flow. The AquaChlor Free Chlorine Monitoring System is also EPA compliant according to Method 334.0.
Manufactured by: Thermo Scientific
Model: DataStick Aquachlor Chlorine Sensor
Drinking water production and distribution
Monitoring sanitised process water
Monitoring sterilisation of glassware
Chlorine detection during reverse osmosis / ultrapure water
Measurement System Performance | |
Ranges | 0 to 5 ppm and 0 to 20 ppm |
Resolution | 0.005 ppm |
Accuracy | 2% or ±10 ppb (whichever is greater) |
Step Response Time | 90% in 90 seconds |
Operational Environment | |
Temperature Range | 0 °C to 45 °C (32 °F to 113 °F) |
Maximum Pressure | 15 psig @ 45 °C |
System Flow Rate in Chamber | 200 to 250 mL/min |
Free Chlorine Operation |
When chlorine and pH DataSticks are connected to the AV38 local display, HOCl and ClO- dissociation curves are pH compensated and used to calculate free chlorine present. A stable pH value can also be entered manually. |
Power Requirements † | |
Voltage Range | 10 to 30 VDC |
Maximum Power | 200 mW |
Typical Power | 120 mW |
Construction | |
Process Electrodes | Gold cathode, silver anode |
Membrane | PTFE/FEP |
O-rings | Viton® |
Sensor Head Material | Noryl® |
DataStick Material | PEEK or CPVC |
Weight | 1.2 lbs |
Units of Measure | |
Measurement Units | ppm, free chlorine |
Temperature Units | °C, °F |
Calibration ‡ | |
Sample | 1 point |
Zero | 1 point |
Temperature | point |
Other Configuration Options | |
Sensor Filter | 0 to 100 seconds |
Temperature Filter | 0 to 100 seconds |
Approvals and Ratings | |
Immunity & Emissions | CE Certified 89/336/EEC: CISPER 11, EN61000 (-4-2,-4-3,-4-4,-4-6, 4-8) |
Safety | cULus Listed; 367G E303570 |
Hazardous Locations | Haz Loc Class 1, Division 2, Groups A, B, C, D. Max Ambient 50 °C |
† Note: Class II DC power supply required ‡ Note: Precalibrated at the factory |