Alpha DO 2000 Dissolved Oxygen Controller/Transmitter

  • Choice of Versions Available Two versions available depending on application requirements
  • Warranty This product comes complete with a one year warranty
  • User Friendly Easy to use and large screen for easy viewing
Product Options

Overview

Eutech's Alpha DO 2000 Dissolved Oxygen Controller/Transmitter is ideal for use in a wide range of applications ranging from water treatment and monitoring of pharmaceutical and food processing. The Alpha DO 2000 meter displays values in mg/L or % air saturation's both are selectable from the easy to use menu options, and comes in both Galvanic and Amperometric versions. Calibration is a quick and easy process using atmospheric air for 100% air saturation.

The Galvanic Electrode option is rugged and long lasting and requires no warm-up time and prevents zero drift by recreating H20 within the electrode. This action prevents change of pH to the electrode and allows it to recycle within the probe. The end result is the galvanic sensors have long lifespans and require low maintenance costs.

The Amperometric dissolved oxygen electrode option contains special membranes that are designed to require almost zero maintenance. The brilliance of theses unique membranes is they stay stable even under harsh ambient conditions and high pressure. The result is this enables the sensors to capture accurate DO readings within short response time at required flow as low as 0.2m/s.

This product is covered by a one year warranty.

Manufactured by: Eutech Instruments
Model: Alpha DO 2000 Dissolved Oxygen Controller/Transmitter

Services offered for this product

  • Sales
  • Rental
  • Installation
  • Calibration
  • Maintenance
  • IoT Cloud Compatible

Applications

General
Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.

Specification

Dissolved Oxygen
Range 0.00 to 25.00 mg/L or ppm;
0.0 to 300.0 %
(For TSDOCTP2000W)
0.00 to 20.00 mg/L or ppm;
0.0 to 200.0 %
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Resolution 0.01 mg/L or ppm; 0.1 %
Accuracy ±1.5 % of full scale reading
(For TSDOCTP2000W)
±1 % of full scale reading
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Temperature
Range -10.0 to 125.0 °C / 14.0 to 257.0 °F
Resolution 0.1 °C / 0.1 °F
Accuracy ±0.5 °C / ±1.0 °F
Sensor Pt100/Pt1000 (jumper selectable);
2 or 3 wire
(For TSDOCTP2000W)
NTC 22 kOhm thermistor
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Compensation
Temperature Compensation Auto/manual
Salinity Compensation 0.0 to 50.0 ppt (manual setting and automatic correction)
Pressure Compensation 0.740 to 3.000 bar ; 555 to 2250 mmHg ;
10.73 to 43.51 psi (manual setting and automatic correction)
Set Point and Controller Functions
Set Point 1 (SP1) /
Set Point 2 (SP2)
0.00 to 25.00 mg/L or ppm;
0.0 to 300.0 %
(For TSDOCTP2000W)
0.00 to 20.00 mg/L or ppm;
0.0 to 200.0 %
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Switching DO Hysteresis 0 to 10.0 %
(For TSDOCTP2000W)
0.1 to 1.0 mg/L or
1.0 to 10.0 %
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Function (Switchable) P/PI control (pulse length/pulse frequency/proportional integral); limit control; off
Adjustable Period With Pulse Length Controller 0.5 to 20 sec
Adjustable Period With Pulse Frequency Controller 60 to 120 pulse/min
Integral Action Time (IAT) 0.0 to 999.9 min
Pickup/Dropout Delay 0 to 1999 sec
Wash Cycle 0.1 to 199.9 hr
Wash Duration 1 to 1999 sec
Contact Outputs 1 SPDT, 3 SPST relays
Switching Voltage/ Current/Power 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA
(For TSDOCTP2000W)
Max. 250 VAC / max. 3 A /
max. 600 VA
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Alarm Functions
Function (Switchable) Steady or fleet (pulse)
Pickup Delay 0 to 1999 sec
Switching Voltage / Current / Power 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA
1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA
(For TSDOCTP2000W)
Max. 250 VAC / max. 3 A /
max. 600 VA
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Electrical Data and Connections
Transmitter Function Two 0/4 to 20 mA outputs for Dissolved Oxygen values and temperature, galvanically isolated
CU 22 Function 22 mA current output
(For TSDOCTP2000W)
�??????????????????�?????????????????�????????????????�???????????????�??????????????�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?�¢??
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Isolated Output Voltage 12 V ±0.5 V (max. 50 mA)
Hold Function Switch To freeze output current and deactivate control relays
Load Max. 600 Ohm
DO Input 2-pin terminal
Connection Terminal 5-pin, 8-pin, 9-pin & 13-pin terminal, detachable blocks
(For TSDOCTP2000W)
2x 3-pin, 8-pin, 9-pin & 13-pin terminal blocks
(For TSDOCTP2000WPG)
3-pin, 9-pin & 19-pin�?????????????????�????????????????�???????????????�??????????????�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?� 
terminal blocks
(For TSDOCTP2000PPG)
Display
LCD UV coat, backlit 14 segments display with symbols for status information
Backlight On/off selectable with four level of brightness control
Power Supply
Input 80 to 250 VAC/DC ; 50/60 Hz ; 10 VA
Main Fuse 315 mA, anti surge, 250 V
(For TSDOCTP2000W)
250 mA, anti surge
(For TSDOCTP2000WPG &
TSDOCTP2000PPG)
Electromagnetic Compliance
Emitted Interference According to EN 61326
Immunity to Interference According to EN 61326
Environmental Conditions
Operating Temperature Range 0 °C to 50 °C
Max. Relative Humidity 80 % up to 31 °C decreasing linearly to 50 % at 40 °C
Mechnical Specifications
Dimensions (WxHxD) 144 x 144 x 111.5 mm
(For TSDOCTP2000W)
144 x 144 x 110 mm
(For TSDOCTP2000WPG)
175 x 96 x 96 mm
(For TSDOCTP2000PPG)
Weight 745 g (unit) / 1100 g (packed)
(For TSDOCTP2000W & TSDOCTP2000WPG)
700 g (unit) / 850 g (packed)
(For TSDOCTP2000PPG)
Ingress Protection IP66 (NEMA 4X)
(For TSDOCTP2000W & TSDOCTP2000WPG)
IP54 (front panel)
(For TSDOCTP2000PPG)