Eutech's Alpha DO 2000 Dissolved Oxygen Controller/Transmitter is ideal for use in a wide range of applications ranging from water treatment and monitoring of pharmaceutical and food processing. The Alpha DO 2000 meter displays values in mg/L or % air saturation's both are selectable from the easy to use menu options, and comes in both Galvanic and Amperometric versions. Calibration is a quick and easy process using atmospheric air for 100% air saturation.
The Galvanic Electrode option is rugged and long lasting and requires no warm-up time and prevents zero drift by recreating H20 within the electrode. This action prevents change of pH to the electrode and allows it to recycle within the probe. The end result is the galvanic sensors have long lifespans and require low maintenance costs.
The Amperometric dissolved oxygen electrode option contains special membranes that are designed to require almost zero maintenance. The brilliance of theses unique membranes is they stay stable even under harsh ambient conditions and high pressure. The result is this enables the sensors to capture accurate DO readings within short response time at required flow as low as 0.2m/s.
This product is covered by a one year warranty.
Manufactured by: Eutech Instruments
Model: Alpha DO 2000 Dissolved Oxygen Controller/Transmitter
General
Useful for monitoring temperature and control of DO in wastewater treatment and aquaculture applications. Use with valves, blowers or aerators to ensure proper system operation.
Dissolved Oxygen | |
Range | 0.00 to 25.00 mg/L or ppm; 0.0 to 300.0 % (For TSDOCTP2000W) 0.00 to 20.00 mg/L or ppm; 0.0 to 200.0 % (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Resolution | 0.01 mg/L or ppm; 0.1 % |
Accuracy | ±1.5 % of full scale reading (For TSDOCTP2000W) ±1 % of full scale reading (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Temperature | |
Range | -10.0 to 125.0 °C / 14.0 to 257.0 °F |
Resolution | 0.1 °C / 0.1 °F |
Accuracy | ±0.5 °C / ±1.0 °F |
Sensor | Pt100/Pt1000 (jumper selectable); 2 or 3 wire (For TSDOCTP2000W) NTC 22 kOhm thermistor (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Compensation | |
Temperature Compensation | Auto/manual |
Salinity Compensation | 0.0 to 50.0 ppt (manual setting and automatic correction) |
Pressure Compensation | 0.740 to 3.000 bar ; 555 to 2250 mmHg ; 10.73 to 43.51 psi (manual setting and automatic correction) |
Set Point and Controller Functions | |
Set Point 1 (SP1) / Set Point 2 (SP2) |
0.00 to 25.00 mg/L or ppm; 0.0 to 300.0 % (For TSDOCTP2000W) 0.00 to 20.00 mg/L or ppm; 0.0 to 200.0 % (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Switching DO Hysteresis | 0 to 10.0 % (For TSDOCTP2000W) 0.1 to 1.0 mg/L or 1.0 to 10.0 % (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Function (Switchable) | P/PI control (pulse length/pulse frequency/proportional integral); limit control; off |
Adjustable Period With Pulse Length Controller | 0.5 to 20 sec |
Adjustable Period With Pulse Frequency Controller | 60 to 120 pulse/min |
Integral Action Time (IAT) | 0.0 to 999.9 min |
Pickup/Dropout Delay | 0 to 1999 sec |
Wash Cycle | 0.1 to 199.9 hr |
Wash Duration | 1 to 1999 sec |
Contact Outputs | 1 SPDT, 3 SPST relays |
Switching Voltage/ Current/Power | 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA (For TSDOCTP2000W) Max. 250 VAC / max. 3 A / max. 600 VA (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Alarm Functions | |
Function (Switchable) | Steady or fleet (pulse) |
Pickup Delay | 0 to 1999 sec |
Switching Voltage / Current / Power | 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA (For TSDOCTP2000W) Max. 250 VAC / max. 3 A / max. 600 VA (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Electrical Data and Connections | |
Transmitter Function | Two 0/4 to 20 mA outputs for Dissolved Oxygen values and temperature, galvanically isolated |
CU 22 Function | 22 mA current output (For TSDOCTP2000W) �??????????????????�?????????????????�????????????????�???????????????�??????????????�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?�¢?? (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Isolated Output Voltage | 12 V ±0.5 V (max. 50 mA) |
Hold Function Switch | To freeze output current and deactivate control relays |
Load | Max. 600 Ohm |
DO Input | 2-pin terminal |
Connection Terminal | 5-pin, 8-pin, 9-pin & 13-pin terminal, detachable blocks (For TSDOCTP2000W) 2x 3-pin, 8-pin, 9-pin & 13-pin terminal blocks (For TSDOCTP2000WPG) 3-pin, 9-pin & 19-pin�?????????????????�????????????????�???????????????�??????????????�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?� terminal blocks (For TSDOCTP2000PPG) |
Display | |
LCD | UV coat, backlit 14 segments display with symbols for status information |
Backlight | On/off selectable with four level of brightness control |
Power Supply | |
Input | 80 to 250 VAC/DC ; 50/60 Hz ; 10 VA |
Main Fuse | 315 mA, anti surge, 250 V (For TSDOCTP2000W) 250 mA, anti surge (For TSDOCTP2000WPG & TSDOCTP2000PPG) |
Electromagnetic Compliance | |
Emitted Interference | According to EN 61326 |
Immunity to Interference | According to EN 61326 |
Environmental Conditions | |
Operating Temperature Range | 0 °C to 50 °C |
Max. Relative Humidity | 80 % up to 31 °C decreasing linearly to 50 % at 40 °C |
Mechnical Specifications | |
Dimensions (WxHxD) | 144 x 144 x 111.5 mm (For TSDOCTP2000W) 144 x 144 x 110 mm (For TSDOCTP2000WPG) 175 x 96 x 96 mm (For TSDOCTP2000PPG) |
Weight | 745 g (unit) / 1100 g (packed) (For TSDOCTP2000W & TSDOCTP2000WPG) 700 g (unit) / 850 g (packed) (For TSDOCTP2000PPG) |
Ingress Protection | IP66 (NEMA 4X) (For TSDOCTP2000W & TSDOCTP2000WPG) IP54 (front panel) (For TSDOCTP2000PPG) |