PH/ORP control is now supremely easy using the Alpha pH 200 limit controller, this device features 6 sub menus all controlled via a four button keypad. Set up, Calibration and password protection is all simply controlled by the user in a few simple steps.
Clear uninterrupted readings are delivered even in electronically noisy environments by using the symmetrical mode whilst the two SPDT relays with independent hysteresis produced effective high/low set points limit control with minimal relay chattering.
User friendly options of Eutechs' Alpha pH 200 are the choice of automatic or manual temperature compensation, in addition to this is the three wire system which compensates error due to cable resistance. 85 to 250 VAC. 50/60 Hz or DC variable input allows the user to set up this controller in a wide range of supply voltages and full scale 4 to 20 mA galvanically isolated current output for process control.
The Alpha pH 200 features a heightened security mode which enables the user to set two levels of password to protect against unauthorised tampering and access only to calibration and set up menus via pre set passwords.
This product is covered by a 1 year warranty.
Manufactured by: Eutech Instruments
Model: Alpha pH 200 pH / ORP Controller / Transmitter
General
Ideal for virtually any batch type application where pH or ORP control or adjustment is needed. Use as ORP monitor for ozone systems and general purpose pH monitor for all types of water treatment and chemical processes.
Aquaculture
Use for pH and ORP control in fish ponds and tanks.
Industrial
Use to treat batches of incoming process water, rinse water treatment, recirculating system and wastewater treatment. Suitable for pH or ORP control of plating tanks and chemical processing tanks. Ideal for low cost monitor with alarms for batch and process applications. Perfect for wastewater neutralization in small and medium sized batches.
pH | |
Range | 0.00 to 14.00 pH |
Resolution | 0.01 pH |
Accuracy | ±0.01 pH |
ORP | |
Range | -999 to 1000 mV |
Resolution | 1 mV |
Accuracy | ±2 mV |
Temperature | |
Range | -10 to 110 °C |
Resolution | 0.1 °C |
Accuracy | ±0.5 °C |
Sensor | Pt100; 2 or 3 wire |
Compensation | Auto/manual (0 to 100 �?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?�ºC) |
Set Point and Controller Functions | |
Set point 1 (SP1)/�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?� set point 2 (SP2) |
0.00 to 14.00 pH or -999 to 1000 mV |
Switching pH Hysteresis | 0.00 to 2.00 pH |
Switching ORP Hysteresis | 0 to 300 mV |
Function | Limit control |
Contact Outputs | 2 SPDT relays |
Switching Voltage / Current / Power | Max. 250 VAC / max. 3 A / max. 600 VA |
Electrical Data And Connections | |
Transmitter Function | 4 to 20 mA scalable outputs for pH/ORP, galvanically isolated |
Load | 200 Ohm |
pH / ORP Input | BNC (1012�?????????????�????????????�???????????�??????????�?????????�????????�???????�??????�?????�????�???�??�?� impedance); asymmetrical/symmetrical |
Connection Terminal | 3-pin, 7-pin & 9-pin terminal, detachable blocks |
Display | |
LED | 7 segments display |
Power Supply | |
Input | 85 to 250 VAC, 50/60 Hz |
Main Fuse | 250 mA, anti-surge, S504 Bussman |
EMC Specifications | |
Emitted Interference | According to EN 61326 |
Immunity To Interference | According to EN 61326 |
Environmental Conditions | |
Operating Temperature Range | -10 to 50 °C |
Max. Relative Humidity | 10 to 95 % (non-condensing) |
Mechanical Specifications | |
Dimensions (WxHxD) | 96 x 48 x 150 mm |
Weight | 300 g (unit) / 350 g (packed) |
Ingress Protection | IP50 |