RS Hydro are proud to be UK distributors of the improved Eutech Alpha pH 2000D Controller/Transmitter and combination electrode system which uses a unique system that ensures more resistance to contamination or fouling in harsh wastewater applications. The improved system uses a pH glass bulb in place of the conventional reference system this enables a wide pH range of -2.00 to 16.00 pH at two decimal accuracy. Replaceable salt bridge and reference solution add lifespan to the electrode when junctions clog.
This instrumentation can be used to control and measure pH and ORP simultaneously with master-slave operation by placing two controllers side by side and when used in ORP mode is capable of measuring in mV or % concentration, which feature independent calibration modes.
The pH Differential Electrode:
The Eutech Aplha pH 2000D Controller/Transmitter and combination electrode system is able to be wall mouted, pipe mounted or panel mounted depending on the application. The compact design of the electrode and the universal 1.5" NPT mounting threads enable optimal mounting positions.
This is the perfect piece of equipment if you require a reliable, long lasting and cost-saving pH measurement system for demanding environments.
Manufactured by: Eutech Instruments
Model: Alpha pH 2000D pH/ORP Controller/Transmitter
General
Useful for any batch or on-line type application that requires accurate pH or ORP control
Industrial
Ideal for chemical processing, aquarium, pharmaceutical, food processing, waste control industries and hydroponics
Water Purification/Treatment
Use for batch and on-line control of incoming process water, rinse water treatment, waste water treatment and recirculating system
Regulatory
Hook to recorder to document data for regulatory compliance
pH | |
Range | -2.00 to 16.00 pH |
Resolution | 0.01 pH |
Accuracy | ±0.01 pH |
ORP | |
Range | -1000 to 1000 mV / 0 to 100 % |
Resolution | 1 mV / 0.1 % |
Accuracy | ±1 mV / ±0.2 % |
Temperature | |
Range | -10.0 to 110 °C / 14.0 to 230.0 °F |
Resolution | 0.1 °C / 0.1 °F |
Accuracy | ±0.5 °C / ±1.0 °F |
Sensor | NTC 300; 2 wire |
Compensation | Auto/manual (independent process/CAL temperature) |
Set Point and Controller Functions | |
Set Point 1 (SP1)/ Set Point 2 (SP2) | -2.00 to 16.00 pH or -1000 to 1000 mV or 0 to 100 % |
Switching pH Hysteresis | 0.1 to 1 pH |
Switching ORP Hysteresis | 10 to 100 mV or 1 to 10.0 % |
Function (Switchable) | P/PI control (pulse length/pulse frequency/proportional integral); limit control; off |
Adjustable Period with Pulse Length Controller | 0.5 to 20 sec |
Adjustable Period with Pulse Frequency Controller | 60 to 120 pulse/min |
Integral Action Time (IAT) | 0 to 999.9 min |
Pickup/Dropout Delay | 0 to 2000 sec |
Wash Cycle | 0.1 to 200.0 hr |
Wash Duration | 1 to 2000 sec |
Contact Outputs | 1 SPDT, 3 SPST relays |
Switching Voltage / Current / Power | 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA |
Alarm Functions | |
Function (Switchable) | Steady or fleet (pulse) |
Pickup Delay | 0 to 2000 sec |
Switching Voltage / Current / Power | 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA |
Alarm Functions | |
Function (Switchable) | Steady or fleet (pulse) |
Pickup Delay | 0 to 2000 sec |
Switching Voltage / Current / Power | 1/8 HP: at 125 VAC / max. 0.74 A / max. 93 VA 1/8 HP: at 250 VAC / max. 0.37 A / max. 93 VA |
Electrical Data and Connections | |
Transmitter Function | Two 0/4 to 20 mA scalable outputs for pH/ORP and temperature, galvanically isolated |
CU22 Function | 22 mA current output |
Isolated Output Voltage | 12 V ±0.5 V (max. 50 mA) |
Hold Function Switch | To freeze output current and deactivate control relays |
Load | Max. 600 Ohm |
pH / ORP Input | 2-pin terminal (Differential) |
Connection Terminal | 5-pin, 8-pin, 9-pin & 13-pin terminal, detachable blocks |
Display | |
LCD | UV coat, backlit 14 segments display with symbols for status information |
Backlight | On/off selectable with four levels of brightness control |
Power Supply | |
Input | 80 to 250 VAC/DC ; 50/60 Hz ; 10 VA |
Main Fuse | 315 mA time delay, 250 V, Bussmann BK/GDC-315 mA |
Pollution Degree | 2 |
Transient Overvoltage Category | II |
EMC Specifications | |
Emitted Interference | According to EN 61326 |
Immunity to Interference | According to EN 61326 |
Environmental Conditions | |
Operating Temperature Range | 0 to 40 °C |
Max. Relative Humidity | 80 % up to 31 °C decreasing linearly to 50 % at 40 °C |
Mechanical Specifications | |
Dimensions (WxHxD) | 144 x 144 x 110 mm |
Weight | 950 g (unit) / 1100 g (packed) |
Ingress Protection | IP66 (NEMA 4X) |