With a hard elastomer rubber lined bore, the MAG 5100W magflo meter is suitable for all water applications including those with very low flow rates. It can be used for DN25 to 1200 (1 inch to 48 inch). The kit is supplied as standard complete with integral grounding electrodes.
The hard lining guarantees consistent accuracy throughout the temperature and pressure range, whilst the soft elastomer facing provides high abrasion resistance and eliminates the need for gaskets. It is highly resistant to a wide range of chemicals.
MCERTS
The Siemens MAG 5100W is now MCERTS certified meeting the Environment Agency's performance requirements. View downloads for certificate.
Manufactured by: Siemens-Milltronics
Model: MAG 5100W Magflo Meter
Water abstraction
Water treatment
Water distribution network (leak detection management)
Custody transfer water meters
Irrigation
Waste water treatment
Filtration plant (e.g. reverse osmosis and ultra filtration)
Industrial water applications
Measuring Range | 0 to 10 m/s |
Nominal Sizes | From DN 25 to DN 2000 (1” to 78”) |
Accuracy | 0.2 % ±2.5 mm/s |
Operating Pressure | Max. 16 bar (Max. 150 psi) |
Ambient Temperature | From -40 to 70 °C (-40 to 158 °F) |
Medium Temperature | From -10 to 70 °C (14 to 158 °F) |
Liners | EPDM NBR hard rubber Ebonite hard rubber |
Electrodes | Hastelloy C-276 Built-in grounding electrodes |
Material | Carbon steel, with corrosion resistant two-component epoxy coating |
Drinking Water Approvals | EPDM: WRAS, NSF/ANSI Standard 61, DVGW 270, ACS and BelgAqua NBR: NSF/ANSI Standard 61, WRAS Ebonite: WRAS |
Custody Transfer Approvals | OILM R 49 MI-001 |
General Approval | MCERTS Sira Certificate No. MC080136/00 |